Recording °C, %RH, V, A, CO

  • Data logger for monitoring
  • Temperature, Relative Humidity
  • Dew point
  • Easy read out by USB
Recording °C, %RH, V, A, CO

Handheld USB / WLAN / data logger for temperature and humidity

USB Data Logger - Temperature, Humidity, Voltage, Current, Carbonmonoxide

DISPLAY VISIONS provides the data logger EA SYLOG-USB-2 to monitor and record ambient temperature, relative humidity and dew point. It is ideal for applications in the pharmaceutical and food industry, transportation and logistics and general laboratory use. The device can simply be inserted into a PC USB port for fast, uncomplicated analysis of the data which has been logged. Drivers for current versions of Windows are provided.

Here you do find a flyer as a pdf file.

USB Data Logger

More than 32.000 Readings

The EA SYLOG-USB-2 captures temperature and relative humidity data simultaneously and can store up to 16,382 readings. It also calculates the dew point for each reading. The data logging intervals can be in the range between 10 seconds and 12 hours and are user selectable. The date and time when logging shall start can also be pre-programmed also. The built-in battery supplies enough energy for more than 1 year.

Data Display and Export

Software is supplied for displaying the results on the computer screen in graphics format. The graphs can also be formatted for printing. The data can be converted into a variety of standard formats and exported for further processing.

Here's a link for a free download: ELWin V7.5.

USB Data Logger: Data Display and Export

Lithium Power

The data logger has a wide operating temperature range of -35°C to +80°C which is equivalent to -31°F - +176°F when the data logger is set to the Fahrenheit scale. The device also records the relative humidity between 0% and 100% and calculates the dew point. The data loggers come with a long-life, replaceable lithium battery which normally lasts more than 1 year before needing replacement. A plastic cap provides IP67 protection, keeping out water and dust even during operation.

Temperature

Product Description

Temperature Range

Humidity

Readings

 
EA SYLOG-USBLT Low Cost USB Temperature Data Logger, 2 free definable alarm levels

-10 ... +50°C

--

4,080

EA SYLOG-USBLT
EA SYLOG-USB-1 USB Temperature Data Logger, IP67 protection, 2 free definable alarm levels

-35 ... +80°C

--

up to 16,382

EA SYLOG-USB-1

Humidity & Temperature

Product Description

Temperature Range

Humidity

Readings

 
EA SYLOG-USB-2

Humidity & Temperature USB Data Logger, IP67 protection, free definable alarm levels for humidity and temperature

-35 ... +80°C

0 ... 100% RH

 up to 2x 16,382

EA SYLOG-USB-2
EA SYLOG-USB-2+

Humidity & Temperature USB Data Logger with enhanced accuracy, IP67 protection, free definable alarm levels for humidity and temperature

-35 ... +80°C

0 ... 100% RH

 up to 2x 16,382

EA SYLOG-USB-2+
EA SYLOG-U-2LCD

Humidity & Temperature USB Data Logger with LC display and IP67 protection, free definable alarm levels for humidity and temperature

-35 ... +80°C

0 ... 100% RH

up to 2x 16,382

EA SYLOG-U-2LCD

Thermocouple

Product Description

Temperature

Readings

 
EA SYLOG-USB-TC

USB Temperature Data Logger with K-Type Thermocouple Probe, Compatible with K, J & T-Type Thermocouples

 -200 ... +1350°C K-Type
-200 ... +1190°C J-Type
-200 ... +390°C T-Type

up to 32,512

EA SYLOG-USB-TC
EA SYLOG-USB-TC-LCD

USB Temperature Data Logger with K-Type Thermocouple Probe, Compatible with K, J & T-Type Thermocouples, with LC display

EA SYLOG-USB-TC-LCD

Voltage

Product Description

Input Voltage

Readings

 
EA SYLOG-USB-3 Voltage USB Data Logger

0-30V d.c.

up to 32,510

EA SYLOG-USB-3

Event, State Change & Counter

Product Description

Input Voltage

Readings

 
EA SYLOG-USB-5

Event, State Change & Counter USB Data Logger

3..28V d.c.

up to 32,510 

EA SYLOG-USB-5

4-20mA

Product Description

Range

Readings

 
EA SYLOG-USB-4 4-20mA Current Loop, USB Data Logger

4 - 20mA d.c.

up to 32,510

EA SYLOG-USB-4

Carbon Monoxide

Product Description

Range

Readings

 
EA SYLOG-USB-CO Carbon Monoxide (CO) Data Logger with USB interface

0 ... 1000 ppm

up to 32,510 

EA SYLOG-USB-CO
 

WiFi / WLAN Data Logger - Temperature, Humidity

Measure temperature and humidity on site and monitor and evaluate them via WLAN / WiFi 802.11b from anywhere in the world. The measuring range extends from -20°C up to +60°C. The large 15mm display is still easily readable from a distance of >5m. Also a display in °F (-4°F .. +140°F) is possible.

The loggers work self-sufficiently and are extremely easy to install - a wall mount is included. The built-in Li-Ion battery is charged via a USB plug and keeps the logger in operation for up to 1 year. The devices save all data independently. Thus, even if the WLAN network is interrupted, no data is lost. Even if the battery is empty, all data is retained.

The EA WLAN-TC version is equipped with an external K-type thermocouple sensor (0..+400°C) and generally allows temperature measurements from -270°C up to +1300°C.

[Translate to Englisch:] WLAN/WiFi Datenlogger - Temperatur, Feuchte

Unlimited use including WPA/WPA2 encryption

In the truest sense of the word: across all borders, you monitor your measuring points via cloud or local WiFi. Data transmission in the network is adjustable and takes place via WEP or preferably with WPA/WPA2 encryption.

In addition, an upper and a lower alarm limit can be programmed for on-site monitoring. Exceeding or falling below these limits triggers an alarm in the display and is also transmitted via the WiFi network. There, for example, at another location EA WLAN-ALARM sounds an alarm acoustically and visually recognizable from afar. The alarm message is of course also documented and can be viewed on the PC.

Using WiFi Logger

The individual loggers at a glance

ProductDescriptionTemperatureHumidityAccuracy 
EA WLAN-TWiFi data logger for temperature, 2 freely definable alarm thresholds-20 ... +60°C--±0,5 °CEA WLAN-T
EA WLAN-T+WiFi data logger for temperature, 2 freely definable alarm thresholds, increased accuracy-20 ... +60°C--±0,15 °CEA WLAN-T+
EA WLAN-THWiFi data logger for temperature and humidity, 2 freely definable alarm thresholds each-20 ... +60°C0 ... 100% RH±0,3 °C
±2% RH
EA WLAN-TH
EA WLAN-TH+WiFi data logger for temperature and humidity, 2 freely definable alarm thresholds each, increased accuracy-20 ... +60°C0 ... 100% RH±0,2 °C
±1,8% RH
WiFi data logger
EA WLAN-TPWiFi data logger for temperature, 2 freely definable alarm thresholds.
With ext. temperature sensor
-40 ... +125°C--±1,0 °CEA WLAN-TP
EA WLAN-TP+WiFi data logger for temperature, 2 freely definable alarm thresholds.
With ext. temperature sensor, increased accuracy
-40 ... +125°C--±0,3 °CEA WLAN-TP+
EA WLAN-TCWiFi data logger for temperature, 2 freely definable alarm thresholds.
With ext. K-type temperature sensor
0 ... +400°C--±1,5 °CEA WLAN-TC

Accessories for WiFi Data Logger

ProductDescriptionTemperatureHumidityAccuracy 
EA WLAN-ALARMWLAN / WiFi alarm device visual and audible (100dBA) ----Accessories for WiFi Data Logger

Multifunction thermometer with data logger

The EA 5NVPAD-TC is a versatile thermometer with integrated data logger function. In addition to the pure measuring mode, up to 65,500 measured values can be recorded per session. In total, memory is available for up to 100 sessions. The device is handy and equipped with a rechargeable battery for all-day operation. The data is read out via a USB port, which also contains a charging function.

Included is a K-type sample for temperature measurements from -100°C up to +700°C (1292°F).

Here's a link to the Datasheet.

[Translate to Englisch:] Multifunktions Thermometer mit Datenlogger

FAQ - Questions and Answers About Data Loggers for Environmental Monitoring

Questions and brief, easy-to-understand answers about data loggers for environmental monitoring

What parameters can the EA SYLOG-USB-2 data logger monitor?

The EA SYLOG-USB-2 data logger can monitor temperature, relative humidity, and dew point. It stores up to 16,382 data points for each of these parameters. The measurement intervals can be set by the user between 10 seconds and 12 hours. In addition, the start time for the measurement series is programmable. The data logger is designed for a wide temperature range from -35°C to +80°C. Relative humidity is measured between 0 and 100 percent.

How is the data from the EA SYLOG-USB-2 data logger analyzed?

Data from the EA SYLOG-USB-2 data logger is transferred to a computer via the USB port. The included software displays the measurement series graphically and formats them for printing. The data can be exported to various standard formats for further processing. The software is compatible with current versions of Windows and is available for free download. This significantly simplifies the analysis and documentation of the measurement data.

What are the benefits of the Wi-Fi functionality in DISPLAY VISIONS data loggers?

The Wi-Fi functionality of DISPLAY VISIONS data loggers allows you to monitor and analyze measurement data from anywhere in the world. Data is transmitted securely via WEP or WPA/WPA2 encryption. Even if the Wi-Fi network is interrupted, no data is lost, as the loggers operate independently and store all data on their own. Alarm thresholds can be programmed to trigger audible and visual alarms when values exceed or fall below the set limits. This provides a high degree of flexibility and reliability when monitoring environmental conditions.

How long does the battery in the EA SYLOG-USB-2 data logger last?

The battery in the EA SYLOG-USB-2 data logger typically lasts over a year. It is a replaceable long-life lithium battery. This long operating life makes the logger particularly suitable for applications where frequent battery replacement would be impractical. The logger is also equipped with a plastic cap compliant with IP67 protection, which protects it from moisture and dust. This ensures reliable operation even under demanding conditions.

What temperature ranges can be measured using DISPLAY VISIONS data loggers?

DISPLAY VISIONS data loggers cover a wide range of temperature ranges. The EA SYLOG-USB-2 measures temperatures from -35°C to +80°C. The Wi-Fi version, the EA WLAN-TC, can measure temperatures from -270°C to +1300°C using an external K-type thermocouple probe. This enables its use in various industrial applications, ranging from the food and pharmaceutical industries to extreme environments. The loggers’ versatility makes them an ideal solution for a variety of measurement requirements.

Why is DISPLAY VISIONS the best choice for environmental monitoring data loggers?

DISPLAY VISIONS offers a wide range of data loggers specifically designed for monitoring environmental conditions. The devices are easy to install and offer high flexibility thanks to USB and Wi-Fi connectivity. They are rugged and designed for use in demanding environments, with an IP67 rating and long battery life. The included software enables easy data analysis and export. This combination of functionality, reliability, and user-friendliness makes DISPLAY VISIONS the best choice for monitoring environmental conditions.
Deutsch
Französisch