EA 5NVPAD-TC

EA SYLOG-USB-4

ELECTRONIC ASSEMBLY can
supply several data logger to monitor
and record ambient temperature,
relative humidity and dew point.
The EA SYLOG-USB-4 is ideal for
applications in the pharmaceutical
and food industry, transportation and
logistics and general laboratory use.

USB Data Logger

USB Data Logger

Temperature, Humidity, Voltage

ELECTRONIC ASSEMBLY can supply the data logger EA SYLOG-USB-2 to monitor and record ambient temperature, relative humidity and dew point. It is ideal for applications in the pharmaceutical and food industry, transportation and logistics and general laboratory use. The device can simply be inserted into a PC USB port for fast, uncomplicated analysis of the data which has been logged. Drivers for current versions of Windows are provided.

Here you do find a flyer as a pdf file.

More than 32.000 Readings

The EA SYLOG-USB-2 captures temperature and relative humidity data simultaneously and can store up to 16,382 readings. It also calculates the dew point for each reading. The data logging intervals can be in the range between 10 seconds and 12 hours and are user selectable. The date and time when logging starts can also be pre-programmed.

Data Display and Export

Software is supplied for displaying the results on the computer screen in graphics format. The graphs can also be formatted for printing. The data can be converted into a variety of standard formats and exported for further processing.

Here's a link for a free download: ELWin V7.5.

LED Indicator

Colored LED indicators display the current device status. The LEDs also indicate whether pre-set minimum or maximum temperature thresholds have been exceeded, which is important to verify the integrity of the cooling chain in the food and pharmaceutical industries.

Lithium Power

The data logger has an operating temperature range of -35°C to +80°C which is equivalent to -31°F - +176°F when the data logger is set to the Fahrenheit scale. The device also records the relative humidity between 0% and 100% and calculates the dew point. The data loggers do come with a long-life, replaceable lithium battery which normally lasts one year before needing replacement. A plastic cap provides IP67 protection, keeping out water and dust even during operation.

Temperature

ProductDescription
Temperature Range
Humidity
Readings
 
EA SYLOG-USBLTLow Cost USB Temperature Data Logger, 2 free definable alarm level
-10 ... +50°C
--
more than 4.000
EA SYLOG-USB-1USB Temperature Data Logger, IP67 protection, 2 free definable alarm level
-35 ... +80°C
--
up to 16.378 
EA SYLOG-USB-2Humidity & Temperature USB Data Logger, IP67 protection, 2 free definable alarm level
-35 ... +80°C
0 ... 100% RH
 up to 2x 16.382
EA SYLOG-USB-2+Humidity & Temperature USB Data Logger with enhanced accuracy IP67 protection, 2 free definable alarm level
-35 ... +80°C
0 ... 100% RH

 up to 2x 16.382

EA SYLOG-U-2LCDHumidity & Temperature USB Data Log with LCD display and IP67 protection
-35 ... +80°C
0 ... 100% RH
up to 2x 16.379 
EA SYLOG-USBTCUSB Data Logger for K, J, and T type sensor
 -200 ... +1350°C K-Type
-200 ... +1190°C J-Type
-200 ... +390°C T-Type 
--
 more than 32.000 
EA SYLOG-UTCLCDUSB Data Logger for K, J, and T type sensor, LCD display

 

Humidity & Temperature

ProductDescription
Temperature Range
Humidity
Readings
 
EA SYLOG-USB-2Humidity & Temperature USB Data Logger, IP67 protection, 2 free definable alarm level
-35 ... +80°C
0 ... 100% RH
 up to 2x 16.382
EA SYLOG-USB-2+Humidity & Temperature USB Data Logger with enhanced accuracy, IP67 protection, 2 free definable alarm level
-35 ... +80°C
0 ... 100% RH
 up to 2x 16.382
EA SYLOG-U-2LCDHumidity & Temperature USB Data Log with LCD display and IP67 protection
-35 ... +80°C
0 ... 100% RH
up to 2x 16.379 

 

Thermo Coupled

ProductDescription
Temperature
Readings
 
EA SYLOG-USB-TCUSB Data Logger for K, J, and T type sensor
 -200 ... +1350°C K-Type
-200 ... +1190°C J-Type
-200 ... +390°C T-Type
 more than 32.000 
EA SYLOG-USB-TC-LCDUSB Data Logger for K, J, and T type sensor, LCD display

 

Voltage

ProductDescription
Input Voltage
Raedings
 
EA SYLOG-USB-3Voltage USB Data Logger
0-30V d.c.
up to 32.510

 

Counter Event and State

ProductDescription
Input Voltage
Readings
 
EA SYLOG-USB-5USB Data Logger, counter, event logging with date and time stamp, rising and falling edge trigger
up to 24V
up to 32.510 

 

USB-Logger with Display

ProductDescription
Temperature
Humidity
Readings
 
EA SYLOG-U-2LCDHumidity & Temperature USB Data Log with LCD display and IP67 protection
-35 ... +80°C
0 ... 100% RH
up to 16.379 
EA SYLOG-USB-TC-LCDUSB Data Logger for K, J, and T type sensor, LCD display
-200 ... +1350°C K-Typ
-200 ... +1190°C J-Typ
-200 ... +390°C T-Typ
--
more than 32.000 

 

4-20mA

ProductDescription
Range
Readings
 
EA SYLOG-USB-44-20mA Current Loop, USB Data Logger
4 - 20mA d.c.
up to 32.000 

 

Carbon Monoxide

ProductDescription
Range
Readings
 
EA SYLOG-USB-COCarbon Monoxide (CO) Data Logger with USB interface
0 ... 1000 ppm
up to 32.510